Banner

Rapid Deployment Boards

These Boards are for use when the need to rescue is considered to be urgent and requires no instructions for the BA wearer other than the need to insert his BA tally in the slot provided.

608444
60844

This Board is for use when the need to rescue is considered to be urgent and requires no instructions for the BA wearer other than the need to insert his BA tally in the slot provided.
At a later time of entry the designated Entry Control Officer will use the information on the Rapid Deployment Board to transfer accountability of the BA wearers to the Standard 12 Slotted BA Board as follows:-
Remove tallies from RDB the lapsed time will stop counting and remain visible. By subtracting the lapsed time reading from the present time shown on the 12 slotted Entry Control board, he then writes real entry time on tally and inserts it in the Entry Control Board. At this point he is able to enter Whistle time in the usual way with the use of the Calculator.
LED Indicator Lights
Green : Start-up, Push Buttons.
Left Button : Off Switch only (5 Sec delay to avoid accidental), Other Button : Illumination
The sounder is not an alarm and should only be considered as a tap on the shoulder to ECO. It sounds 5 bleeps every 5 minutes.

Various Slot Rapid Deployment BA Board.

The rapid deployment Entry control board comprises of a timing device and positions for the insertion of four BA tallies. When the switch is depressed by the insertion of the first tally, this automatically operates the timing device and the lapsed time is indicated on the Board. When both tallies are removed the lapsed time will stop and remain visible until the power button is pressed.

Procedure.

Upon arrival at the incident the BA Wearer removes the key and tally from DSX MKI or MKII Distress signal and places it in the slot provided in the BA Board. No further action is required by the BA Wearer, who is then able to enter the incident. The BA Board will then automatically monitor elapsed time. As more personnel become available and a full Entry Control is initiated, the BA Entry Control Officer transfers the information from the Rapid Deployment Board to the standard BA Board in the normal manner, hence maintaining Accountability.

 
B.A boards are not supplied with Identification tally.

Size 2 man = 175mm * 210mm * 30mm (W * H * D) weight = 670g

Size 4 man = 180mm * 310mm * 30mm (W * H * D) weight = 1006g

Size 5 man = 180mm * 365mm * 30mm (W * H * D) weight = 1128g
 
Part Number 6084 (4 man) for other tally key size’s use part number followed by /2, /3, /5 etc.

12 Man Rapid Deployment Board

Part Number 6083 (12 man) for other tally key slot size’s use part number followed by /2, /3, /5 etc

12mrd
12mrdtp

Top view

12mbot

Bottom View

B.A Identification Tally

ChinaGraph pencil (box of 12)

6005
tally

Standard BA Board with extra features, including Rapid Deployment Facility Procedure.The BA Wearers remove Tally key from the DSX and place it in the slots provided in the BA Board. No further action is required by the BA wearer, who is then able to enter the incident. At some later moment of time when the BA Entry Control has set up the BA Board, say 10 minutes after BA entry. He is able to enter details directly onto board simply by referring to the elapsed time, and the present time. e.g. If present time is 1:30 then time of entry would be 1:20 , he would then turn calculator to 1:20 , and then by reading the tally cylinder content, say 180 Bar he could then enter real time of whistle on the calculator.
Caution HARD WORK WILL REDUCE DURATION TIME.

Note! Refer to Technical Bulletin 1/1997 CNP3 Rapid Deployment Procedures.
 

B.A boards are not supplied with Identification tally.

Size 12 man = 385mm * 780mm * 20mm (W * H * D) 

Part No: 6083

weight = 4378g

Tripod With or without Light